Goose Creek Cooling Tower

After Hurricane Hugo destroyed the water cooling tower at the Williams Station Power Plant in June of 1989, engineers with South Carolina Electric & Gas (SCE&G) needed a high-performing coating system to protect their new replacement unit from corrosion. “They wanted to get the plant up and running, so this project was on a fast track,” recalled Dan Anderson, Tnemec coating consultant. “At the same time, they needed a coating system that would last as long as possible because you have to shut the entire plant down every time you recoat a cooling tower.”

Approximately 400 gallons of coatings were used on the water tower and connecting pipes, which were prepared by abrasive blast cleaning according to SSPC-SP10. Three coats of a polyamide epoxy, Series 66 Hi-Build Epoxoline, were applied to the large pipe interior at 4.0 to 6.0 mils DFT per coat. The piping’s exterior received two coats of the epoxy and a finish coat of an aliphatic acrylic polyurethane, Series 73 Endura-Shield, which is highly resistant to abrasion, wet conditions and exterior weathering. “All of the coatings were spray-applied at the jobsite because of the tight deadline,” Anderson noted.

More than 17 years later, the cooling tower’s coating system continues to provide corrosion protection, according to Anderson. Several other coating projects have followed, including a major job involving a selective catalytic reduction (SCR) unit designed to reduce air pollution at Williams Station, which is the second-largest fossil fuel plant in SCE&G’s system. That project used a zincrich polyurethane primer, Series 90-97 Tneme-Zinc, applied at 2.5 to 3.5 mils, followed by a finish coat of Series 73 Endura-Shield at 4.0 to 6.0 mils. “Those coatings were all spray- applied in the shop, then touched up in the field,” Anderson said. “About 4,000 gallons of coating were used for that project, which turned out great.”

“We know the power industry, which is why South Carolina Electric & Gas has used our coatings for more than 20 years,” Anderson added. “All their plants are using our coatings and it’s pretty amazing that during those 20 years we’ve never had a failure.”

    Project Information

    Location
    Goose Creek, South Carolina

    Completion
    September 1989

    Owner
    South Carolina Electric & Gas

    Field Applicator
    Dunlap, Inc. of South Carolina

    Engineer
    SCE&G Engineering of Goose Creek, South Carolina

    Printer Friendly Version

    PP_Williams_Station_Cooling_Profile

    Contact Your Rep

    Looking for Some Local Coatings Guidance?

    Reach out to one of our knowledgable and reliable representatives near you.

    How to Purchase

    Ready to Order Tnemec?

    We're ready to help. Click below to learn more about our purchasing process.

    Sustainable Building

    Need Coatings for LEED Projects?

    Tnemec offers a long list of low VOC coatings built to protect sustainable structures.

    Continue Exploring in the color tool

    Close

    Color Swatch packet

    You can use our Color Tool page to explore our available colors and request swatches of colors you like.

    Sorry, there is a maximum of 6 color swatches.

    Request swatch packet

    Continue Exploring in the color tool

    Close