Series V140
Pota-Pox Plus
This product has been discontinued. Please contact your local sales representative for further assistance.
Generic Type
Polyamidoamine Epoxy
Common Usage
Innovative potable water coating which offers high-build edge protection and allows for application at a wide range of temperatures (down to 35°F or 2°C with 44-700 Accelerator). For use on the interior and exterior of steel or concrete tanks, reservoirs, pipes, valves, pumps and equipment in potable water service.
Special Qualifications
Certified by NSF International in accordance with ANSI/NSF Std. 61. Series V140 is qualified for use on tanks of 50,000 gallons (189,270L) capacity or greater, valves 2 1/2 inches (6 cm) in diameter or greater and fittings 3/4 inch (2 cm) in diameter or greater. Reference Tnemec's certified product listing at ww.nsf.org for details on maximum allowable DFT.
Conforms to AWWA D 102 Inside Systems No. 1 and No. 2 (with or without 44-700). Conforms to AWWA C 210 (without 44-700). Contact your Tnemec representative for systems and additional information.
Number of Components
Two: Part A (amine) and Part B (epoxy) — One (Part A) to one (Part B) by volume.
HAPS
Unthinned: 2.1 lbs/gal solids
Thinned 2.5% (#4): 2.3 lbs/gal solids
Colors
1211 Red, 1255 Beige, 00WH Tnemec White, 15BL Tank White. Note: Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur.
Recommended DFT
2.0 to 10.0 mils (50 to 225 microns) per coat. Note: Dry film thickness that exceeds published recommendations but is in compliance with SSPC PA-2 and ANSI/NSF Std. 61 certifications, is acceptable. Note: The number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Volatile Organic Compounds
Unthinned: 1.95 lbs/gallon (234 grams/litre)
Thinned 2.5% (#4): 2.08 lbs/gallon (250 grams/litre) †
Topcoats
Interior: Series 22, FC22, 264, 265, L140, L140F, N140, N140F, V140, V140F, 141, 406.
Exterior: Series 22, 27, 27WB, 30, 66, L69, L69F, N69, N69F, V69, V69F, 72, 73, 118, L140, L140F, N140, N140F, V140, V140F, 141, 156, 157, 161, 180, 181, 446, 700, V700, 701, V701, 740, 750, 1026, 1028, 1029, 1074, 1074U, 1075, 1075U, 1077, 1078, 1078V, 1080, 1081, 1094, 1095, 1096, 1224. Note: When topcoating with Series 700, V700, 701 or V701, an intermediate coat of Series 73, 1075, 1075U, 1095 or 1096 is required. Note: The following recoat times apply for Series
V140: Immersion Service—Surface must be scarified by blasting with fine abrasive after 60 days. Atmospheric Service—After 60 days, scarification or an epoxy tie-coat is required. When topcoating with Series 740 or 750, recoat time for V140 is 21 days. Note: When topcoating with Series 406, recoat times will vary with temperature. Reference the Series 406 product data sheet for specific recoat times. Contact your Tnemec representative for specific recommendations.
Volume Solids
67.0 ± 2.0% (mixed—A, B & 44-700 Epoxy Accelerator) †
Theoretical Coverage
1,070 mil sq ft/gal (27.2 m²/L at 25 microns). See APPLICATION for coverage rates. †