Series 10V
Tnemec Primers
Generic Type
Modified Alkyd
Common Usage
Chemically active, rust-inhibitive primer for ferrous metals. This low VOC primer provides extended weathering for shop and field priming of structural and miscellaneous steel. Series 10-99W can also be used as a primer for wood substrates.
View more product detailsProduct Data Sheets
- English_Series_V10_Tnemec_Primers_pds.pdf
- French_Series_V10_Tnemec_Primers_pds.pdf
- Spanish_Series_V10_Tnemec_Primers_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
- 1009 Gray
- 99 Red
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Recommended DFT
2.0 to 3.5 mils (50 to 90 microns) per coat.
Number of Components
One
Volatile Organic Compounds
Unthinned: 2.74 lbs/gallon (328 grams/litre)
Thinned 1%: 2.74 lbs/gallon (328 grams/litre)
Volume Solids
58 ± 2.0%
Theoretical Coverage
930 mil sq ft/gal (22.8 m²/L at 25 microns). See APPLICATION for coverage rates.
HAPS
Unthinned: 0 lbs/gal solids
Thinned 1%: 0 lbs/gal solids
Curing Time
Temperature | To Touch | Dry Through | To Recoat |
---|---|---|---|
75°F (24°C) | 30 minutes | 4-6 hours | 12-16 hours |
Curing time varies with surface temperature, air movement, humidity and film thickness.
Topcoats
Series 2H, 2HS, 30, 82HS, 113, 114, 115, 1026, 1028, 1029. Note: Some systems are not for use on surfaces that are continually wet or sweat frequently. Reference the applicable topcoat data sheet for additional information.
Note: Series V10 must cure three days before topcoating with Series 1026, 1028 or 1029.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep