Series 90-97

Tneme-Zinc

Generic Type

Aromatic Urethane, Zinc-Rich

Common Usage

An advanced technology, two-component, moisture-cured, zinc-rich primer providing extraordinary performance. It’s user friendly and rapid curing so chemical- and corrosion-resistant topcoats can be applied the “same-day.” Also used for field touch-up of inorganic zinc coating. Application methods include “dry-fall” under certain conditions (see Application).

Special Qualifications

Series 90-97 meets AISC requirements of Class B surface with a mean slip coefficient no less than 0.50 and a tension creep not in excess of .005 inches (.13mm).

Tneme-Zinc uses a zinc pigment which meets the requirements of ASTM D 520 Type III and contains less than .002% lead. This level qualifies it to be classed as "non-lead" (less than 0.009% lead by weight) as defined in 16 CFR Part 1303 of the Consumer Product Safety Commission regulations. Conforms to SSPC Paint 20, Type II.

This product is part of a coating system tested in accordance with ISO 12944-6 (2018). Contact your Tnemec representative for coating system test results.

View more product details

Colors

  • Reddish-Gray

View Available Colors

View available colors in our Color Tool; you can also select and request color swatches.

Number of Components

Two: Part A and Part B

Volume Solids

63.0 ± 2.0% (mixed)

Topcoats

Series 1, 6, 27, 27WB, 46H-413, 66, L69, L69F, N69, N69F, V69, V69F, 73, 104, 113, 114, 115, 135, 161, 394, 1028, 1029, 1074, 1074U, 1075, 1075U
Note: Certain topcoat colors may not provide one-coat hiding depending on method of application. Contact your Tnemec representative. Note: Series 90-97 must be exterior exposed for three days prior to topcoating with Series 1028 or 1029. Note: Series 90-97 must be exterior exposed for one day prior to topcoating with Series 27WB.

Curing Time

Without 44-710

|Temperature †||To Handle||To Recoat|
|75°F (24°C)||1 hour||4 hours|
|65°F (18°C)||1 1/2 hours||5 hours|
|55°F (13°C)||2 hours||6 hours|
|45°F (7°C)||2 1/2 hours||7 hours|
|35°F (2°C)||3 hours||8 hours|
---† 50% relative humidity. Curing time will vary with surface temperature, humidity and film thickness.
Note: For faster curing, low humidity and low-temperature applications, add No. 44-710 Urethane Accelerator (see separate product data sheet).

Recommended DFT

2.5 to 3.5 mils (65 to 90 microns) per coat.

HAPS

Unthinned: 5.12 lbs/gal solids
Thinned 2.5%: 5.41 lbs/gal solids (No. 2 Thinner); 5.13 lbs/gal solids (No. 3 Thinner)
Thinned 10%: 6.27 lbs/gal solids (No. 2 Thinner); 5.16 lbs/gal solids (No. 3 Thinner)

Theoretical Coverage

1,011 mil sq ft/gal (24.8 m²/L at 25 microns). See APPLICATION for coverage rates.

Volatile Organic Compounds

Unthinned: 2.68 lbs/gallon (321 grams/litre)
Thinned 2.5% (No. 2 or No. 3 Thinner): 2.79 lbs/gallon (334 grams/litre)
Thinned 10% (No. 2 or No. 3 Thinner): 3.10 lbs/gallon (371 grams/litre)

Still have questions? Request the information you’re looking for:

Request Info

How to Purchase

Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep

Continue Exploring in the color tool

Close

Color Swatch packet

You can use our Color Tool page to explore our available colors and request swatches of colors you like.

Sorry, there is a maximum of 6 color swatches.

Request swatch packet

Continue Exploring in the color tool

Close