Series 90-97
Tneme-Zinc
Generic Type
Aromatic Urethane, Zinc-Rich
Common Usage
An advanced technology, two-component, moisture-cured, zinc-rich primer providing extraordinary performance. It’s user friendly and rapid curing so chemical- and corrosion-resistant topcoats can be applied the “same-day.” Also used for field touch-up of inorganic zinc coating. Application methods include “dry-fall” under certain conditions (see Application).
Special Qualifications
Series 90-97 meets AISC requirements of Class B surface with a mean slip coefficient no less than 0.50 and a tension creep not in excess of .005 inches (.13mm).
Tneme-Zinc uses a zinc pigment which meets the requirements of ASTM D 520 Type III and contains less than .002% lead. This level qualifies it to be classed as "non-lead" (less than 0.009% lead by weight) as defined in 16 CFR Part 1303 of the Consumer Product Safety Commission regulations. Conforms to SSPC Paint 20, Type II.
This product is part of a coating system tested in accordance with ISO 12944-6 (2018). Contact your Tnemec representative for coating system test results.
View more product detailsProduct Data Sheets
- English_Series_90_97_Tneme_Zinc_pds.pdf
- French_Series_90_97_Tneme_Zinc_pds.pdf
- Spanish_Series_90_97_Tneme_Zinc_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
- Reddish-Gray
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Number of Components
Two: Part A and Part B
Volume Solids
63.0 ± 2.0% (mixed)
Topcoats
Series 1, 6, 27, 27WB, 46H-413, 66, L69, L69F, N69, N69F, V69, V69F, 73, 104, 113, 114, 115, 135, 161, 394, 1028, 1029, 1074, 1074U, 1075, 1075U
Note: Certain topcoat colors may not provide one-coat hiding depending on method of application. Contact your Tnemec representative. Note: Series 90-97 must be exterior exposed for three days prior to topcoating with Series 1028 or 1029. Note: Series 90-97 must be exterior exposed for one day prior to topcoating with Series 27WB.
Curing Time
Without 44-710
|Temperature †||To Handle||To Recoat|
|75°F (24°C)||1 hour||4 hours|
|65°F (18°C)||1 1/2 hours||5 hours|
|55°F (13°C)||2 hours||6 hours|
|45°F (7°C)||2 1/2 hours||7 hours|
|35°F (2°C)||3 hours||8 hours|
---† 50% relative humidity. Curing time will vary with surface temperature, humidity and film thickness.
Note: For faster curing, low humidity and low-temperature applications, add No. 44-710 Urethane Accelerator (see separate product data sheet).
Recommended DFT
2.5 to 3.5 mils (65 to 90 microns) per coat.
HAPS
Unthinned: 5.12 lbs/gal solids
Thinned 2.5%: 5.41 lbs/gal solids (No. 2 Thinner); 5.13 lbs/gal solids (No. 3 Thinner)
Thinned 10%: 6.27 lbs/gal solids (No. 2 Thinner); 5.16 lbs/gal solids (No. 3 Thinner)
Theoretical Coverage
1,011 mil sq ft/gal (24.8 m²/L at 25 microns). See APPLICATION for coverage rates.
Volatile Organic Compounds
Unthinned: 2.68 lbs/gallon (321 grams/litre)
Thinned 2.5% (No. 2 or No. 3 Thinner): 2.79 lbs/gallon (334 grams/litre)
Thinned 10% (No. 2 or No. 3 Thinner): 3.10 lbs/gallon (371 grams/litre)
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep