Series 280
Tneme-Glaze
Generic Type
Modified Polyamine Epoxy
Common Usage
A glaze-like corrosion resistant coating for walls, ceilings, floors and other surfaces; resistant to frequent pressurized hot water and detergent cleaning. Used as a topcoat/sealer for heavy duty wall and floor systems or in a stand-alone high-performance function. Excellent chemical, stain- and abrasion-resistance for a variety of substrates.
Special Qualifications
Series 280 meets the requirements of LEED-Low-Emitting Materials, Collaborative for High Performance Schools-Paints & Coatings, WELL Building Standard-VOC Restrictions , and Living Building Challenge–Healthy Interior Performance. Contact your Tnemec representative for more information.
View more product detailsProduct Data Sheets
- English_Series_280_Tneme_Glaze_pds.pdf
- French_Series_280_Tneme_Glaze_pds.pdf
- Spanish_Series_280_Tneme_Glaze_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
- 05BL Gainesboro
- 25BL Fountain Bleu
- 42BL Blue Channel
- 04BR Desert Sands
- 15BR Pale
- 68BR Twine
- 91GN Balsam
- 31GR Slate Gray
- 33GR Gray
- 35GR Black
- 46GR Sinker
- 28RD Monterrey Tile
- 02SF Lemon Yellow/Safety
- 17SF Candy Apple Red/Safety
- 00WH White
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Volatile Organic Compounds
Unthinned: 0.16 lbs/gallon (19 grams/litre)
Thinned 5% (No. 2 Thinner): 0.52 lbs/gallon (63 grams/litre)
Thinned 5% (No. 42 Thinner): 0.50 lbs/gallon (59 grams/litre) †
Number of Components
Two: Part A and Part B (2 Parts A to 1 Part B by volume)
Surfacer/Filler/Patcher
Series 130, 215, 218, 1254. Note: A repair kit of 201, with Part C fumed silica or Series 280 with fumed silica, is available for small patching/surfacing repairs. For more extensive repairs and additional information, contact your Tnemec representative or Tnemec Technical Services.
Primers
Concrete: Self-priming or Series 201, 205, 208, 233, 237, 238, 241.
CMU: Self-priming over filled CMU
Wall board, Wood & Drywall: Self-priming or Series 151, 201, 233. Note: For taping joints on wall board or drywall in areas that will be frequently wet, subject to chemical cleaning, thermal shock, impact, and VHP (or similar) cleaning, use Sheetrock brand Durabond 90. For taping joints on wood or cement board, use Series 273 Part D fiberglass tape and Series 215 as taping compound. Reference Technical Bulletin 21-118.
Curing Time
Temperature | To Topcoat | To Place in Service |
---|---|---|
75°F (24°C) | 8-72 hours | 24 hours |
Note: If more than 72 hours have elapsed between coats, the coated surface must be mechanically abraded before topcoating.
Volume Solids
100% (mixed) †
Recommended DFT
Horizontal: 6.0 to 12.0 mils (150 to 305 microns) per coat.
Vertical: 4.0 to 8.0 mils (100 to 205 microns) per coat
Additional coats may be required for appearance or hiding.
Theoretical Coverage
1,604 mil sq ft/gal (39.4 m²/L at 25 microns). See APPLICATION for coverage rates. †
Finish
Gloss. (Roller application provides an orange peel finish.)
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep