Series 241

Ultra-Tread MVT

Generic Type

Polyurethane Modified Concrete

Common Usage

Ultra-Tread MVT is a low odor, slurry applied, high performance moisture control base layer designed to reduce moisture vapor emissions prior to the application of non-breathing, polymer floor topping finishes. Ultra-Tread MVT is a self-priming, base coat that can be applied to 10 day old concrete. It can withstand moisture vapor transmission up to 20 lbs (per ASTM F 1869) and relative humidity up to 99% (per ASTM F 2170). Note: Series 241 must be broadcast to refusal with aggregate, color quartz or decorative flake typically completed within 10 to 15 minutes of application. Color quartz and/or decorative flake systems will require an additional broadcast layer using Series 222, 224, 237, 238, 256, 257 or 286, clear to obtain a uniform appearance and texture before applying the desired clear finish coats. This will typically result in a total system thickness of approximately 1/8".

Special Qualifications

Formulated with antimicrobial properties. Does not support bacteria or fungal growth. Contact your Tnemec representative for specific test results.

Series 241 was tested in accordance with, and passed, the California Dept. of Public Health (CDPH) Standard Method v1.2 and meets the requirements of LEED v4.1 Low-Emitting Materials, Collaborative for High Performance Schools-Paints & Coatings, Living Building Challenge Materials Petal 10, and WELL Building Standard v2 X06 VOC Restrictions.

View more product details

Volatile Organic Compounds

Parts A & B: 0.05 lbs/gallon (5.6 grams/litre)
Parts A, B & C: 0.03 lbs/gallon (3.9 grams/litre)

Topcoats

Series 222, 233, 237, 238, 239, 246, 247, 248, 252SC, 256, 257, 280, 280FC, 281, 282, 284, 285, 286, 290, 291, 294, 295, 296, 297. Note: These topcoats may only be used when recommended aggregate has been broadcast to refusal into the wet Series 241. Note: If Series 247 (tinted), 248 (tinted), 290, 291 or 297 is selected for the finish coat over a broadcast system, a grout coat of Series 222, 233, 237 or 238 (tinted), 256 (tinted), 280 or 281 is required. If Series 247 (clear), 248 (clear), 285, 294, 295 or 296 is selected for the finish coat over a broadcast system, a grout coat of 222, 233, 237 or 238 (clear), 256 (clear) or 284 is required.

Curing Time

Temperature Min. Recoat Light Traffic Place in Service
75°F (24°C) 6 hours 8 hours 12 hours

For full resistance to chemicals and heavy traffic, 24 hour cure is needed. Curing time varies with surface temperature, air movement, humidity and film thickness. Note: For faster curing and low temperature applications, add No. 44-714 Ultra-Tread Accelerator, see separate product data sheet for cure information.

Primers

Self-priming

Intermediate

Series 222, 223, 224, 233, 237, 237SC, 238, 239, 239SC, 252SC, 256, 257. Note: Series 241 must be broadcast to refusal with aggregate, colored quartz or decorative flake before topcoating. Broadcast aggregate or colored quartz at an approximate rate of 0.8 lb per sq ft and decorative flake at an approximate rate of 0.25 lb per sq ft or 4 to 5 sq ft per pound. The Series 241 base coat will account for approximately 1/8" of the desired system thickness.

Surfacer/Filler/Patcher

Series 241 (extended with aggregate) or Series 243, 244. Patching should be allowed to cure a minimum of six hours prior to placement of the Series 241 to avoid blistering or doming of the Series 241. Series 215, or 201 or 208 mixed with fumed silica, may be used for small patches or crack repairs. Certain high-early strength, cementious repair mortars are also acceptable. Contact Tnemec for further qualifications.

Recommended DFT

46.0 to 52.0 mils (1168 to 1320 microns) applied neat. Film thickness, after broadcasting with aggregate, is approximately 1/8" (3mm). Refer to coverage rates table for more information. Note: Exceeding the recommended coating thickness may result in blistering of the product. Avoid excessive coating thickness by thoroughly filling voids, depressions and cracks with recommended filler or surfacer prior to Series 241 application.

Number of Components

Three—Liquids: Part A & Part B, Aggregate: Part C

Volume Solids

100% (mixed)

Theoretical Coverage

70-80 sq ft (6.50-7.43 m²) per small kit

Still have questions? Request the information you’re looking for:

Request Info

How to Purchase

Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep

Continue Exploring in the color tool

Close

Color Swatch packet

You can use our Color Tool page to explore our available colors and request swatches of colors you like.

Sorry, there is a maximum of 6 color swatches.

Request swatch packet

Continue Exploring in the color tool

Close