Series 217
MortarCrete
Generic Type
Calcium Sulfoaluminate Cementitious Repair Mortar and Concrete
Common Usage
A single-component, ultra rapid setting, hydraulic cementitious resurfacer used to restore deteriorated concrete surfaces or extended with aggregate to make high-strength concrete.
Special Qualifications
Series 217 is acceptable for use on the interior of potable water concrete storage tanks and reservoirs when topcoated with an NSF/ANSI/CAN Std. 61 certified protective coating. Contact your Tnemec representative for approved systems and additional information.
View more product detailsProduct Data Sheets
- English_Series_217_Mortarcrete_pds.pdf
- French_Series_217_Mortarcrete_pds.pdf
- Spanish_Series_217_Mortarcrete_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Number of Components
One
Topcoats
Series 22, FC22, 27WB, 46H-413, L69, L69F, N69, N69F, V69, V69F, 120, L140, L140F, N140, N140F, V140, V140F, 141, 142, 201, 215, 218, 237SC, 239SC, 252SC, 262, 264, 434, 435, 436, 451, 454, 456, 457.
Note: Series 217 must be mechanically prepared in accordance with SSPC-SP13/NACE 6, ICRI-CSP 5 minimum surface profile prior to application of recommended topcoats. Any surface cracks in the Series 217 may require filling with Series 215 or Series 218 to prevent transfer or telegraphing through topcoat. Contact Tnemec Technical Services for additional information.
Curing Time
Temperature | Initial Set | Final Set | To Topcoat |
---|---|---|---|
90°F (32°C) | 30 minutes | 60 minutes | 12 hours |
70°F (21°C) | 60 minutes | 90 minutes | 12 hours |
45°F (7°C) | 90 minutes | 2 hours | 24 hours |
Note: Use Series 211-217 Slow Set additive to extend set time or Series 211-219 Plasticizer to adjust the slump (fluidity). Refer to Series 211-217 Slow Set and Series 211-219 Plasticizer product data sheets for additional information.
Primers
Concrete: Series 217 Bond Coat †
† A thin bond coat (scrub coat) is required for hand placement or low-pressure grout spray applications. Refer to the Series 217 MortarCrete @Surface Preparation and Application Guide@ or Contact Tnemec Technical Services with questions.
Volatile Organic Compounds
0.0 lbs/gallon (0 grams/litre)
Recommended DFT
Resurfacer:
Horizontal/Vertical: 1/4 inch (6 mm) to 4 inches (102 mm)
Overhead: 1/4 inch (6 mm) to 3 inches (76 mm)
Series 217 Concrete: Contact Tnemec Technical Services for nominal thickness limitations.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep