Series 1402
ProPolymer
Generic Type
Elevated Temperature Vinyl Ester
Common Usage
Series 1402 is a food grade, vinyl ester primer for complete FDA-compliant lining systems in concrete, steel or stainless-steel tanks. Fast-cure characteristics allow for quick application of subsequent coats, limiting downtime and facility disruption. Series 1402 is the only approved primer for the ProPolymer food grade product line. Replaces ProPolymer 4808.
Special Qualifications
Complies with the requirements and extractive limitations of US FDA 21 CFR Part 175.300 Resinous and Polymeric Coatings for tanks or other repeated use direct food storage or mixing vessels 5 gallons or greater under conditions of use C-E with all food types. Compliance was based upon raw material supplier documents, and third party analytical and extractive test results (HKGH02404112 and HKGH02409467).
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Volatile Organic Compounds
EPA Method 24
1.67 lbs/gallon (200 grams/litre)
Number of Components
Two: Part A (base) and Part B (catalyst)
Finish
Gloss
Recommended DFT
2.0 mils to 6.0 mils (50 microns to 152 microns).
Surfacer/Filler/Patcher
Series 215, 217, N218, primer with 211-9111 or fumed silica; Series 1402 extended with 211-0211 for direct food contact steel surfaces. Note: Series N218 should be used for filling or patching small areas only. For areas in need of full resurfacing, select one of the other recommended products.
Curing Time
Temperature | To Recoat | Immersion | Maximum Recoat |
---|---|---|---|
90°F (32°C) | 3 hours | 24 hours | 3 days |
75°F (24°C) | 4 hours | 48 hours | 5 days |
60°F (16°C) | 12 hours | 4 days | 7 days |
Recoat times are typical for coating to be dry-to-touch and ready for the next application. Immersion and certain other services may require longer cure times and/or elevated temperature post cure for optimal performance. Direct food contact service requires post cure see Application Guide. Coating that has exceeded its maximum recoat time should be checked for styrene or acetone sensitivity or uniformly scarified to assure secondary bonding. Consult Tnemec Technical Services and Technical Bulletin 22-119 R1.
Theoretical Coverage
1,363 mil sq ft/gal (33.4 m²/L at 25 microns). See APPLICATION for coverage rates
Volume Solids
85.0 ± 2.0% (mixed). Series 1402 contains a reactive monomer and some loss will occur during application and cure. Actual solids by volume will vary depending upon temperature and air movement.