Series 115
Uni-Bond DF
Generic Type
Self-crosslinking Hydrophobic Acrylic
Common Usage
A high-performance, versatile coating appropriate for a variety of uses including:
Exterior Steel: Waterborne, rust-inhibitive coating with excellent adhesion to zinc-rich coatings. Used as a primer, intermediate and finish coat on tanks, vessels and other industrial and architectural metal substrates.
Humid Environments: Primer/finish for two coat applications over prepared galvanized steel and zinc-rich coatings in wet, temperature-controlled exposure areas.
Dry Interior Environments: One or two coat, flash-rust and corrosion resistant primer/finish for overheads. Use on prepared carbon and galvanized steel, aluminum, wood and concrete decks, beams, joists and HVAC.
Note: Uni-Bond DF's "dry-fall" characteristics help reduce the potential for overspray problems on buildings and surrounding property.
Special Qualifications
Series 115 meets the requirements of LEED-Low-Emitting Materials, Collaborative for High Performance Schools-Paints & Coatings, WELL Building Standard-VOC Restrictions, and Living Building Challenge–Healthy Interior Performance. Contact your Tnemec representative for more information.
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
-
This product is available in 433 colors.
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
HAPS
Unthinned: 0.02 lbs/gal solids
Thinned 5%: 0.02 lbs/gal solids
Finish
Eggshell
Topcoats
Series 113, 114, 115, 156, 157, 180, 181, 1026, 1028, 1029, 1094, 1095, 1096. Note: When Series 115 is applied over 90-97, 90G-1K97, 91-H2O or 94-H2O, only itself or Series 1028 or 1029 can be used as topcoats. Note: Reference the latest version of Tnemec Technical Bulletin 14-101 for more information on Series 115 as a primer for high performance finishes.
Curing Time
Temperature | To Touch | To Handle | To Recoat |
---|---|---|---|
75°F (24°C) | 1 hour | 3 hours | 4 hours |
Curing time varies with surface temperature, air movement, humidity and film thickness.
Theoretical Coverage
706 mil sq ft/gal (17.3 m²/L at 25 microns). See APPLICATION for coverage rates. †
Intermediate
Series 115 may be used as an intermediate coat over 1, 90E-92, 90G-1K97, 90-75, 90-97, H90-97, 91-H₂O, 94-H₂O or 394. Series 44-900 Adhesion Promoter must be used when topcoating Series 1 or 394 with Series 115.
Recommended DFT
2.0 to 4.0 mils (50 to 100 microns) per coat.
Number of Components
One
Volume Solids
44.0 ± 2.0% †
Volatile Organic Compounds
Unthinned: 1.09 lbs/gallon (131 grams/litre)
Thinned 5%: 1.09 lbs/gallon (131 grams/litre) †
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep