Series 113
H.B. Tneme-Tufcoat
This product has been discontinued. Please contact your local sales representative for further assistance.
Generic Type
Waterborne Acrylic Epoxy
Common Usage
High performance coating suitable for concrete, steel and other commonly used building materials. Features include high-build, low odor, non-yellowing white and fade resistant colors; easy cleanup and stain-, abrasion-, chemical- and moisture-resistance. Good exterior performance.
Number of Components
Two: One Part A (4.5 gal) and One Part B (1/2 gal)
Volume Solids
44.0 ± 2.0% (mixed) †
HAPS
Unthinned: 2.59 lbs/gal solids
Thinned 5% (No. 59 Thinner): 2.82 lbs/gal solids
Primers
Steel: Series 1, 10, 27, 37H, 66, N69, N69F, 90E-92, 90-97, H90-97, 115, 394, 530. Note: Series 10 and 37H are not recommended for frequently wet conditions. Allow Series 10 to cure one week and 37H to cure 30 days before topcoating. Note: When topcoating Series 1 or 394 with 113, maximum recoat time is three days.
Galvanized Steel and Non-Ferrous Metal: Series 66, N69, N69F, 115
Dense Concrete: Self-priming, Series 130, 218
CMU: Series 54, 130, 218
Drywall: Series 151
Wood: Dry interior environments only, self-priming, Series 10-99W, 151-1051
Finish
Satin
Recommended DFT
4.0 to 6.0 mils (100 to 150 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
Temperature | To Touch | To Handle | To Recoat |
---|---|---|---|
75°F (24°C) | 30-45 minutes | 2-3 hours | 1-2 hours |
Curing time varies with surface temperature, air movement, humidity and film thickness.
Theoretical Coverage
706 mil sq ft/gal (17.3 m²/L at 25 microns). See APPLICATION for coverage rates. †
Colors
Refer to Tnemec Color Guide.
Volatile Organic Compounds
Unthinned
1.90 lbs/gallon (228 grams/litre)
Thinned 5% (No. 59 Thinner)
2.03 lbs/gallon (243 grams/litre) †